allbcis.com

Every brain–computer interface on earth

non-invasive  ·  EEG ·  shipping

ActiveTwo

By BioSemi

Identity

Manufacturer
BioSemi
Model number
—
Codename
—
Aliases
BioSemi ActiveTwo, ActiveTwo Mk2
Generation
Mk2
Country of origin
NL
Released
—
Announced
—
Discontinued
—
Status
shipping

Classification

Invasiveness
non-invasive
Modalities
EEG, ECG, EMG, EOG
Primary modality
EEG
Direction
read
Categories
research-grade
Form factor
modular
Use cases
high-density EEG / ERP research, BSPM / body surface potential mapping, ECG / EMG research, source-localization studies
Target users
neuroscience-researcher

Electrodes

Total channels
280
Recording channels
264
Reference channels
—
Electrode type
wet-active
Material
Ag/AgCl-sintered
10-20 positions
—
Requires gel
Yes
Requires saline
No
Prep time
—
Reusable
Yes
Disposable
No

Signal acquisition

Sampling rate
2048–16384 Hz
ADC resolution
24 bit
Notch filters
—
Onboard artifact rejection
No

Stimulation

Capable
No

Connectivity

Protocols
optical-fiber, usb-2
Bluetooth
—
Bluetooth profiles
—
Concurrent mode
—
Encryption (transit)
—
Pairing methods
—
Cloud sync
No
Offline recording
No

Power

Sources
rechargeable-li-ion
Battery life (active)
—
Charging port
—
Charging time
—
Battery replaceable
—
Notes
AD-Box runs from an internal rechargeable battery for full mains isolation; data is sent to the host PC over an optical fiber.

Physical

Weight
1100 g
Dimensions
190 mm L × 150 mm W × 120 mm H
Materials
—
Sizes
—
Head circumference
—
Operating temp
—

Software & data

Mobile app
No
Cloud platform
No
Offline mode
No
Subscription required
No
Raw data access
Yes
Export formats
bdf
LSL support
—
Data ownership
user
Apps
ActiView

SDK & developer access

Has SDK
Yes
Open source
Yes
Languages
labview
Web Bluetooth
No
Raw sample access
Yes
BCI paradigms
—
3rd-party integrations
—
Docs
biosemi.com

Regulatory & clinical

FDA status
none
CE mark
No
Certifications
—
Prescription required
No
Pediatric approved
No

Pricing & availability

MSRP
—
Current price
—
Subscription
—
Warranty
—
Return policy (days)
—
Where to buy
Buy at biosemi.comBuy at neurospec.com

Media & links

Official site
biosemi.com
Product page
biosemi.com

Editor’s take

In favor

  • Per-channel 24-bit ADC + DC coupling = reference-class signal quality
  • Active electrodes tolerate high skin impedance and reduce movement artefact
  • Optical-fiber isolation eliminates ground loops and mains noise
  • Open-source ActiView acquisition; native .BDF format readable by every major EEG package

Against

  • Explicitly not a medical device — research-only
  • Quote-based pricing in the high-end research tier
  • Acquisition software runs on LabVIEW — older UX than newer BrainVision Recorder
  • Top sample rates (16 kHz) are limited to 32 channels

Sources & provenance

Last reviewed